GLOBAL LP FW

 

The Swegon GLOBAL LP FW air handling units is a series of efficient and robust units, developed for installers valuing simplicity, contractors that need to keep time and budget and end-users who want the right indoor climate at the right cost.

The GLOBAL LP FW range is specially designed to be integrated in false ceilings and suits small to medium size projects such as retail shops, restaurants, offices, schools, hotels, residential buildings, fitness centers, day-care centers, gyms, theaters and public buildings.

  • Low profile for false ceilings applications
  • Integrated TAC5 controls
  • Temperature efficiency, heat recovery up to 86%
  • Air flows up to 9 000 m³/h or 2500 l/s
  • Cooling energy recovery
  • For indoor and outdoor use

Size overview

LP: Low Profile unit

FW: Forwards Fans

GLOBAL LP FW 450
GLOBAL LP FW 600
GLOBAL LP FW 1000
GLOBAL LP FW 1600
GLOBAL LP FW 2000
  0 500 1000 1500 2000
          (m³/h)

  View of underside   View of underside
 
  LP Right-hand version    Left-hand version
450 Art. no:  886247   Art. no:  886252
       
   View of underside    View of underside

 
 LP Right-hand version   Left-hand version
600 Art. no:  886253   Art. no:  886248
1000 Art. no:  886254   Art. no:  886249
1600 Art. no:  886255   Art. no:  886250
2000 Art. no:  886256   Art. no:  886251
       

Exhaust air  Supply air  
Outdoor air   Extract air  

Brilliant Simplicity – in every step

  • Selection: Every unit has a straight forward article number; one for right-hand units and one for left-hand units. Other parts, like post-heating coils, dampers or outdoor mounting kits are easily selected as accessory for each unit.
  • Offer and Order: You can quickly get an offer for any of the PX GLOBAL air handling units from your local sales representative who will also assist you in taking care of your order.
  • Delivery: Units and accessories are delivered ex-works within 10-15 working days.
  • Start-up and commissioning: One piece units, no mechanical assembly besides accessories and duct work is required on site. Start-up and commissioning is done quickly, due to the build-in TAC5 control on board all the GLOBAL units that includes different running modes and time clocks
  • Usage and Service: Once commissioned the GLOBAL air-handling units do not require much attention. Since all fans are direct driven there are no pulleys and belts and standard maintenance procedures such as change of filters are indicated by a service alarm.

Highly efficient heat exchangers

The highly efficient, Eurovent certified counter-flow heat exchangers. They facilitate supply temperatures and permit or allow transfer of humidity between the two airflows. The exchangers are in “salt-air resistant” aluminium and are suitable for temperatures up to 80°C. They are compliant with the DIN1946 tightness standard and are Eurovent approved according to the EN 308 standard.

Counter-flow heat exchanger (PX)

PX flow

Counterflow plate heat exchangers consist of thin aluminium plates that form parallel air ducts arranged at opposite angles to one another. The warmer extract air heats the plates and transfers heat to the colder supply air. The contact surfaces are large because the air streams flow in parallel and in opposite directions. Temperature efficiency is as high as 83 %. The supply air and extract air have completely separate air passages therefore any possible odours in the extract air cannot be transferred to the supply air. The heat exchanger does not recover moisture to supply air, which is good in facilities with high humidity levels.

Installers choice for 40 years

Focussing on installation cost for projects with small to medium air volumes, short delivery times, off-the-shelf products with easy to use controls for start-up, commissioning.


  • Hardware:

The unit has a casing of prepainted galvanised steel sheet in RAL 9002 and are insulated with 50mm Rockwool and can be delivered as left or right units. Operating temperatures are from -20°C to +50°C

  • Software:

The unit is equipped with the smart control system TAC5 with optional connectivity by Modbus RTU, Modbus TCP IP, Modbus TCP IP over Wifi, Bacnet, KNX. Control panel TACtouch with touch screen.

  • Accessories


   
TAC5 Controller   TAC5 Controller   Electrical heating
         
   
Motorized damper
Flexible connection   Cooling coil
         

 

885315 / 885142

 

LP 450 FW | LP 600 FW | LP 1000 FWLP 1600 FW | LP 2000 FW 

  = Included

  = Available as accessory

GLOBAL LP 450 FW

  GLOBAL LP 450 FW
Air Volume 50-450m³/h
13-125l/s
Inspection side R/L
Counterflow heat exchanger
Rotary heat exchanger -
Can also be used outside -
Filter Class (supply  / extract) G4/G4 (M5/F7)
Filter kit replacement article number 510045
Filter type  Pleated
Filter size in mm and amount (per air direction)
245x295x50
Free cooling ; Full or (Partial)
External pre- / post heating  or cooling (Water/DX)
Internal max pre heater (electrical)  1,5kW
Internal max post heater -
External dampers
Power connection 230 V, 50 Hz, 10 A
maximum current without accessories 3,1A
Motorization Variable speed drive
Thermal efficiency (dry) 80%
SPI int (W/(m³/h)) 0,47
Casing radiated sound power level    (LWA) in dB(A) 59
Weight without accessories  79,1kg
Duct connection (mm) Ø 200
Unit size (L x W x H)

1180 x 710 x 360

Downloads


Find PDFs


91 Hits   Page < 1 | 2 | 3 | 4 | 5 >

   

 



Article Name Type Size Date Add to bucket
Page < 1 | 2 | 3 | 4 | 5 >
CID025006  TAC5- MODBUS RTU_EN Instructions/Manuals 658.68kB 9/28/2017 Add to bucket
CID025045  TAC5- KNX_EN Instructions/Manuals 1.67MB 9/28/2017 Add to bucket
CID025071_CID025072  TAC5 MODBUS TCPIP (Wifi-Ethernet)_EN Instructions/Manuals 1.60MB 9/28/2017 Add to bucket
CID025072  SAT ETHERNET - CONFIG IP Other 25.68kB 10/24/2017 Add to bucket
CID372004  SAT TAC5 BA-KW Quick Instal Instructions/Manuals 337.66kB 9/29/2017 Add to bucket
CID372004  TAC5 SAT BA-KW _EN Instructions/Manuals 3.17MB 9/28/2017 Add to bucket
CID521249_CID521250  Pressure Sensor Instructions/Manuals 349.22kB 2/16/2018 Add to bucket
CID521412  BACnet Gateway GLOBAL Instructions/Manuals 601.60kB 8/8/2017 Add to bucket
CID881020_CID881056  GLOBAL RX 08 TOP R Other 1.70MB 9/15/2017 Add to bucket
CID881021_CID881057  GLOBAL RX 08 TOP L Other 1.59MB 9/15/2017 Add to bucket
CID881022_CID881058  GLOBAL RX 10 TOP R Other 1.79MB 9/15/2017 Add to bucket
CID881023_CID881059  GLOBAL RX 10 TOP L Other 1.67MB 9/15/2017 Add to bucket
CID881024_CID881060  GLOBAL RX 12 TOP R Other 1.79MB 9/15/2017 Add to bucket
CID881025_CID881061  GLOBAL RX 12 TOP L Other 1.73MB 9/15/2017 Add to bucket
CID881026_CID881062  GLOBAL RX 14 TOP R Other 2.05MB 9/15/2017 Add to bucket
CID881027_CID881063  GLOBAL RX 14 TOP L Other 1.98MB 9/15/2017 Add to bucket
CID881028_CID881064  GLOBAL RX 16 TOP R Other 2.05MB 9/15/2017 Add to bucket
CID881029_CID881065  GLOBAL RX 16 TOP L Other 1.98MB 9/15/2017 Add to bucket
CID881060_CID881061  GLOBAL RX TOP 12 - 3D Other 906.34kB 2/16/2018 Add to bucket
CID882838  Disassembly-Assembly Instructions/Manuals 1.66MB 10/25/2017 Add to bucket