GOLD RX/HC
- Max. air flow 34.200 m³/h
- Rotary heat exchanger
- Integrated cooling and heating via reversible heat pump
- Placement indoors/outdoors
- Top, side or L connections
- With controls and HMI
- Certified by Eurovent
- Recycled and renewably produced steel with Magnelis® coating (C5) lowers carbon footprint
All-in-one combined air handling unit and reversible heat pump. The result is fresh air, heating and cooling in a slimline and energy-efficient design. Planning is simplified by the fact that we have already done the integration between the heat pump and the air handling unit for you mechanically and in terms of control. Installation is simplified if you opt to have the unit factory pre-filled, tested and ready to run. The unit is also available in a version for cooling only and is then called GOLD RX/C.
With a focus on sustainability, we are committed to reducing the embodied carbon of our units. By introducing XCarb® recycled and renewably produced steel with Magnelis® coating (C5) inside our units we have reduced the total GWP by around 10% and a GOLD unit now contains roughly 15% recycled material.
Dimensions | Air flow | |||||||
Width mm | Height mm | Length mm | Weigth kg | Min air flow m³/s | Max air flow m³/s | Min air flow m³/h | Max air flow m³/h | |
GOLD RX/HC 11 | 1199 | 1395 | 2989 | 737-835 | 0.45 | 1.1 | 1620 | 3960 |
GOLD RX/HC 12 | 1199 | 1395 | 2989 | 765-868 | 0.5 | 1.2 | 1800 | 4390 |
GOLD RX/HC 14 | 1400 | 1651 | 3210 | 934-1062 | 0.75 | 1.7 | 2700 | 5940 |
GOLD RX/HC 20 | 1400 | 1651 | 3210 | 964-1112 | 0.75 | 2.6 | 2700 | 9500 |
GOLD RX/HC 25 | 1600 | 1911 | 3391 | 1238-1426 | 0.95 | 2.4 | 3420 | 8600 |
GOLD RX/HC 30 | 1600 | 1911 | 3391 | 1300-1460 | 0.95 | 2.5 | 3420 | 8890 |
GOLD RX/HC 35 | 1990 | 2259 | 3772 | 1664-1894 | 1.5 | 3.6 | 5400 | 12900 |
GOLD RX/HC 40 | 1990 | 2259 | 3772 | 1740-1970 | 1.1 | 3.9 | 3960 | 14000 |
GOLD RX/HC 50 | 2318 | 2388 | 3892 | 2138-2396 | 1.4 | 4.9 | 5040 | 17800 |
GOLD RX/HC 60 | 2318 | 2388 | 3892 | 2322-2580 | 1.5 | 5.1 | 5400 | 18500 |
GOLD RX/HC 70 | 2637 | 2740 | 4362 | 3322-3592 | 2 | 6.8 | 7200 | 24400 |
GOLD RX/HC 80 | 2637 | 2740 | 4362 | 3426-3840 | 2.1 | 6.9 | 7560 | 24800 |
GOLD RX/HC Top 11 | 1199 | 1395 | 3349 | 837-867 | 0.45 | 1.1 | 1620 | 3950 |
GOLD RX/HC Top 12 | 1199 | 1395 | 3349 | 865-901 | 0.5 | 1.2 | 1800 | 4270 |
GOLD RX/HC Top 14 | 1400 | 1651 | 3773 | 1088-1156 | 0.75 | 1.7 | 2700 | 5940 |
GOLD RX/HC Top 20 | 1400 | 1651 | 3773 | 1118-1210 | 0.75 | 1.8 | 2700 | 6530 |
GOLD RX/HC Top 25 | 1600 | 1911 | 3773 | 1378-1507 | 0.95 | 2.3 | 3420 | 8210 |